Methyl Acetate Chemical Storage Specifications

Compliant storage and rental solutions for Methyl Acetate (C₃H₆O₂). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Methyl Acetate

Methyl acetate is a volatile solvent. It is therefore used in fast-drying paints and for the manufacture of celluloid adhesives from waste film. Methyl acetate is often used in lacquer solutions to lower the viscosity. Methyl acetate may also be used in perfumery and in dye manufacture.

Structured hazard data

Hazard class
Flammable liquids Category 2
Storage category
Flammable Storage
Flammable
Yes
Flash point
-10 °C / 14 °F
Storage temperature
Ambient
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Ethyl Acetate is not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); and STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE)

Serious Eye Damage/Eye Irritation Category 2 Specific target organ toxicity (single exposure) Category 3 Target Organs - Central nervous system (CNS).

Fire Suppression System

Dry Chemical fire suppression is recommended for Methyl Acetate

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Methyl acetate (C₃H₆O₂). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: Carbon dioxide (CO 2). Dry chemical. Water mist may be used to cool closed containers. Chemical foam. Water mist may be used to cool closed containers.

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Methyl acetate should account for its listed hazards (Flammable liquids Category 2), climate control needs (Ambient), and segregation requirements. Ethyl Acetate is not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); and STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE)

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: pH No information available Melting Point/Range -98 °C / -144.4 °F Boiling Point/Range 57.4 °C / 135.3 °F @ 760 mmHg Flash Point -10 °C / 14 °F

Matched to this chemical

Recommended storage solutions for Methyl Acetate

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Methyl acetate be stored?

Store Methyl acetate in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Flammable liquids Category 2). Climate range guidance: Ambient. Compatibility notes: Ethyl Acetate is not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); and STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE) US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Methyl acetate flammable?

Yes — Methyl acetate is flagged as a flammable hazard in this database (Yes). Flash point: -10 °C / 14 °F. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Methyl acetate?

Methyl acetate is listed as: Flammable liquids Category 2. Serious Eye Damage/Eye Irritation Category 2 Specific target organ toxicity (single exposure) Category 3 Target Organs - Central nervous system (CNS).

What fire suppression is recommended for Methyl acetate?

Dry Chemical fire suppression is generally recommended for Methyl acetate (C₃H₆O₂). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Methyl acetate storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Methyl acetate. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.